Reference Information:
OEM PN: M4683G/A
OEM Yield: 6,000 prints (5%coverage)
Recommended Tools/ Materials
Phillips head screwdriver
Jewelers screwdriver
Cotton swabs
Anakenisis® PCR Cleaner
99% Isopropyl Alcohol
Printer Compatibility Information:
IBM® Network Printer 12
IBM 4312 Cartridge
Apple® LaserWriter 12/640 PS
Instructions:
Separate the Toner Hopper and OPC Drum Unit:
1. Use a spring hook to remove the tension spring connecting the toner hopper
and OPC drum unit (Fig 1).
2. Invert the cartridge (so that the drum shutter is facing up) and locate the lock-
ing pins on each side. This position will prevent the locking pins from falling
onto the surface of the OPC drum when they are pushed in. Push the pins
forward into the cartridge with a jeweler’s precision screwdriver (Fig 2).
Separate halves and set aside the OPC drum unit.
Figure 1
Toner Hopper Disassembly:
1. On the left side of the toner hopper assembly, locate and remove the two
screws holding the gear cover in place (Fig 3A). Make a note of the gear
position for re-assembly.
1. Locate and remove the two screws securing the end brace/cover on the right
side. (Fig 3B). Clean off any conductive grease around the contact point with
alcohol and a cotton swab.
2. Gently lift the magnetic roller from the toner hopper assembly (Fig 4).
Figure 2
Remove the mag drive gear and slide off the bushings at each end.
3. Clean the magnetic roller and bushings with compressed air. Note: Make
sure the conductive plastic at the end of the mag roller is clean.
Wrap mag roller in cloth and set it aside.
4. Locate and remove the two screws securing the doctor blade. Now,
gently pry the right or left side of the metal piece with a flathead
screwdriver until the blade lifts up (Fig 5).
5. Inspect the adhesive strip on the blade for wear. (Replace if necessary). Use
a blower to remove excess toner.
Figure 3A
6. Remove the toner hopper plug and use a vacuum or blower to empty out
IBM® 4312 Cartridge Remanufacturing Instructions… 1
Oasis Imaging Products Technical Support (822) 322-8992 ext 110
Seitenansicht 0
1 2 3 4

Inhaltsverzeichnis

Seite 1 - Figure 3A

1 IBM® 4312 Remanufacturing Instructions Reference Information: OEM PN: M4683G/A OEM Yield: 6,000 prints (5%coverage) Recommended Tools/ M

Seite 2

2 entire toner hopper assembly. Clean all foam pieces and felts under the magnetic roller with a soft bristled brush (if necessary). Re-assembl

Seite 3