Take Apart Safety Guidelines for Taking Apart the Apple Multiple Scan 15AV
Safety Guidelines for Taking Apart the
Apple Multiple Scan 15AV Display
±
Warning:
This product contains high voltage and a high-
vacuum picture tube. To prevent serious injury, review
CRT safety in Bulletins/Safety.
±
Warning:
Never use a grounding wriststrap until after
discharging the CRT and setting up an ongoing ground
connection.
Important:
Whenever the housing of the monitor is removed
and before replacing a module, you must
1 Discharge the CRT and remove the anode cap.
2 Establish an ongoing ground by using a cable with
alligator clips at both ends. Connect one end to the anode
aperture, and connect the other end to the braided ground
strap that wraps around the CRT.
3 With the CRT discharged and the ongoing ground in place,
wear a grounding wriststrap to prevent equipment
damage from static electricity.
Anode Cap
CRT Discharge Tool
Ongoing GroundAnode Aperture
Ground Strap
Note:
The ground strap
and CRT/video board on
newer displays are
somewhat different than
pictured here. Refer to
“Repair Issues” in the
Basics chapter for details.
Seitenansicht 25