CHAPTER 2
PostScript Software
Interpreter Parameters 19
System Parameters 2
System parameters alter the overall configuration of the printer. You can set system
parameters using the setsystemparams operator and read them using the
currentsystemparams operator. You must use a password to change system
parameters. System parameters are not subject to save and restore. Their values
persist across jobs and may persist across power cycles. Table 2-7 lists the system
parameters present in the Personal LaserWriter 320 printer.
MaxOpStack integer 100000 Determines the maximum number of elements
in the operand stack. It may be set to 0 or any
number larger than 0.
MaxPatternItem integer 20000 Determines the maximum number of bytes
occupied by a single cached pattern. It may be
set to 0 or any number larger than 0.
MaxScreenItem integer 12000 Determines the maximum number of bytes
occupied by a single halftone screen. It may be
set to 0 or any number larger than 0. The initial
value is 3000 bytes per MB of installed RAM,
up to a maximum of 12,000 bytes.
MaxUPathItem integer 5000 Determines the maximum number of bytes
occupied by a single cached user path. It may
be set to 0 or any number larger than 0.
MinFontCompress integer 1250 Sets the threshold at which a cached character
is stored in compressed form instead of as a
full pixel array. It may be set to 0 or any
number larger than 0.
VMReclaim integer 0 Enables or disables local garbage collection:
0 enables automatic collection
-1 disables it for local VM
-2 disables it for both local and global VM
VMThreshold integer 40000 This is the frequency of garbage collection. It
is triggered whenever the number of bytes
indicated by the setting has been allocated. It
may be set to 0 or any number larger than 0.
WaitTimeout integer 40 Indicates the current wait timeout, which is the
number of seconds the interpreter waits to
receive additional characters from the host
before it aborts the current job by executing
a timeout error. It may be set to 0 or any
number larger than 0.
Table 2-6 User parameters in the Personal LaserWriter 320 printer (continued)
Key Type Default Description