Xserve (Late 2006/Early 2008)073-1082 Rev. BLogic BoardReplacement InstructionsFollow the instructions in this document carefully. Failure to follow
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 10Caution: Whenever you handle a heat sink, handle it from the slotted sides, not
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 11Caution: Each heat sink is connected to the logic board by a small 2-pin thermal
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 12ProcessorRelease the latch on the metal processor holder.1. Rotate the top of th
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 13Video Mezzanine Card (if installed)Remove the four 8-5-mm long Phillips screws t
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 14Logic BoardStudy the next four images for properly moving the logic board before
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 15Caution: When transferring the logic board, be careful not to ex the logic boar
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 16Disconnect the optical drive cable from the logic board.2. Release the two locki
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 17Following the order shown, loosen the nine thumbscrews that secure the logic boa
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 18Xserve (Early 2008): Packing the Used Logic Board Important: This packing proced
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 19Place the logic board in the box, making sure it is component-side up and positi
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 2Removing the Xserve from a RackAlert users that the server will be unavailable fo
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 20Installing the Replacement Logic BoardImportant: When replacing the logic board,
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 21Following the order shown, use a screwdriver to tighten, but not overtighten, th
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 22Replacing the ProcessorsUnsnap the protective plastic cover from the rst proces
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 23Use the edge of the package that the alcohol wipe came in as a spatula to spread
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 24Note: When installing the processor on the logic board, align the processor notc
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 25Rotate the top of the holder to the closed position.5. Engage the latch on the p
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 26Replacing the Backplane-to-Logic Board I/O CableFold the cable to a 90-degree an
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 27Replacing the Fan ArrayAlign the power connector on the fan array with its conne
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 28Tighten the ve Phillips screws that fasten the airow duct to the fan array, in
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 29Replacing the PCI Riser Cards and Expansion CardsAlign the riser with slot 2 on
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 3Opening the XserveLoosen the thumbscrews at the back of the top cover and slide t
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 30Changing the Ethernet ID LabelReplacing the logic board in the Xserve changes it
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 31Using the Updated Server Serial NumberWhen you use Server Assistant to install M
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 4Power SuppliesPull the handle to release the rst power supply and slide it out o
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 5FB-DIMMsPush down the ejectors on the FB-DIMM slot.1. Holding the FB-DIMM by both
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 6Airow DuctLoosen the ve captive Phillips screws that fasten the airow duct to
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 7Fan ArrayLoosen the two captive thumbscrews that secure the fan array to the encl
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 8Backplane-to-Logic Board I/O CableDisconnect the backplane-to-logic board cable f
Xserve (Late 2006/Early 2008) Logic Board Replacement Instructions 9Processor Heat SinksNote: Server congurations with a single processor have a reg