Monitor Calibration
A monitor must be correctly calibrated before it can accurately reproduce images. The Truelight
node provides a built in tool for the visual calibration of the Shake monitor. It is also possible to
use monitor calibration files which have been created using a Truelight Monitor Probe and
imported into the machine.
Before calibrating the Shake monitor, it should be set up to ensure optimal performance in your
current viewing environment. You should use the controls on the display to set the brightness,
the contrast, and the white point. The FilmLight recommended practice document
RP-FL001
Viewing Environment and Monitor Setup” gives more detailed advice on setting up your viewing
environment - this can be downloaded from the FilmLight website.
The following procedure applies to the visual calibration of the Shake user interface monitor. If
you have an external HD broadcast monitor, Truelight provides two preset calibration options
which may be appropriate for your monitor (see
step 5 on page 8).
Before starting, ensure that the VLUT and user scripts are switched off:
To start the Truelight Monitor Calibration utility:
1 Click on the ‘other’ tool tab
2 This tab should include two Truelight icons - click on the Truelight Calibrate icon:
Î A ‘TLCalibrate’ node will appear in the Node View. This node does not require any inputs or
outputs as it is just being used to generate a series of lineup patterns in the viewer: