22 Chapter 2 Preparing to Install Your Server
To provide access to the server’s back panel and cables, leave at least 24 inches clear
behind the server.
If you are installing multiple servers or other components in the rack, place the
server so that you can easily open and service it. For example, in a multiple-
component installation, the heaviest items—such as an uninterruptible power
supply—are usually placed at or near the bottom of a rack; servers are often located
near the middle of the rack.
For a rack with multiple components, you may want to prepare a list of all equipment
in the rack and the requirements for each unit. Such a list should include the
following information:
Electrical Power
If you plan to install the server in a rack that contains other components, be sure that
the circuitry and power connections are sufficient for the combined power needs of all
components. To plan for safe and adequate power to the server, follow these
guidelines:
Check the documentation for all components in the rack to determine their power
requirements. Also determine that the available power supply for the rack is
sufficient for the planned components.
If you need assistance in determining the power needs of the components in the
rack, consult an electrical expert who is familiar with your facility.
Important: When planning for electrical power, make sure you have more power
than specified for all components. Also make certain that the power load is
distributed evenly among circuits to the rack’s location. Consult an electrician or
other expert if you need assistance with planning for the power needs of your
components.
Make sure that the power connections for the server and all other components are
grounded (according to local and national standards). Consult an electrician if you
need assistance with grounding.
See Appendix A, “Specifications,” for more information about electrical power
requirements for the server.
This model is certified only as a component for use with other equipment, where the
suitability of the combination has been determined by a Nationally Recognized
Testing Laboratory.
Component Power
needed
Clear area
front/back
Height
in rack
Temperature
range
Other
Server 1
Server 2
Storage